cm/controlmapping
Sources
800-53 · CA Assessment, Authorization and Monitoring
CA-6

Authorization

frameworkNIST SP 800-53 Rev 5.2 sectionCA Assessment, Authorization and Monitoring csf 2.0— topics— frameworks2 0 0 11
Official texta. Assign a senior official as the authorizing official for the system;
b. Assign a senior official as the authorizing official for common controls available for inheritance by organizational systems;
c. Ensure that the authorizing official for the system, before commencing operations:
1. Accepts the use of common controls inherited by the system; and
2. Authorizes the system to operate;
d. Ensure that the authorizing official for common controls authorizes the use of those controls for inheritance by organizational systems;
e. Update the authorizations [Assignment: organization-defined frequency].
NIST SP 800-53 Rev 5.2 control statement (public domain)

Wrong or missing mapping? Report it

Equivalents of CA-6 in other frameworks
FrameworkRequirementTitleLinkSource / reason
NIST CSF 2.0—No requirementNo mapping in our dataNo mapping in our data.
ISO 27001Clause 9.3.1Clause 9.3.3General; Management review resultsCrosswalkNIST SP 800-53 → ISO 27001 mapping
CIS v8.1—No requirementNo mapping in our dataNo mapping in our data (most CIS links are editorial: CIS's published crosswalk covers 49 of 153 safeguards).
SOC 2—No requirementNo mapping in our dataNo mapping in our data (SOC 2 links are editorial only).
PCI DSS—No requirementNo mapping in our dataNo mapping in our data.
CMMC—No requirementNo mapping in our dataNo mapping in our data.
HIPAA§164.308(a)(2)§164.308(a)(8)Assigned Security Responsibility; EvaluationCrosswalkNIST HIPAA → SP 800-53 crosswalk
GDPR—No requirementNo mapping in our dataNo mapping in our data (only GDPR's security articles are mapped, editorially).
NIS2—No requirementNo mapping in our dataNo mapping in our data.
Essential Eight—No requirementNo mapping in our dataNo mapping in our data (Essential Eight links are editorial only).
DORA—No requirementNo mapping in our dataNo mapping in our data (DORA links are editorial, and its technical standards are not mapped).
CPS 234—No requirementNo mapping in our dataNo mapping in our data (CPS 234 is principles-based and its links are editorial).
Cyber Essentials—No requirementNo mapping in our dataNo mapping in our data (Cyber Essentials covers five technical controls only).

Crosswalk a published crosswalk (NIST, ENISA, CIS, PCI SSC) makes the link · Editorial ControlMapping's judgement where no crosswalk exists; the reason is shown · Loosely related only shares a CSF 2.0 outcome: worth checking, not a mapping · No mapping in our data nothing mapped in our data; often new work, but check the coverage notes. How links are sourced.