800-53 · PE Physical and Environmental Protection
PE-19
Information Leakage
frameworkNIST SP 800-53 Rev 5.2
sectionPE Physical and Environmental Protection
csf 2.0PR.AA-06
topics—
frameworks1 0 5
Official textProtect the system from information leakage due to electromagnetic signals emanations.NIST SP 800-53 Rev 5.2 control statement (public domain)
Wrong or missing mapping? Report it
| Framework | Requirement | Title | Link | Source / reason |
|---|---|---|---|---|
| NIST CSF 2.0 | PR.AA-06 | Physical access to assets is managed, monitored, and enforced commensurate with risk | No mapping. Only shares CSF PR.AA-06: related, not a mapping | |
| ISO 27001 | A.7.5A.7.8A.8.12 | Protecting against physical and environmental threats; Equipment siting and protection… | Crosswalk | NIST SP 800-53 → ISO 27001 mapping5 loosely related (not mappings) |
| CIS v8.1 | — | No requirement | No mapping in our data | No mapping in our data (most CIS links are editorial: CIS's published crosswalk covers 49 of 153 safeguards). |
| SOC 2 | CC6.4 | Physical access restrictions | No mapping. Only shares CSF PR.AA-06: related, not a mapping | |
| PCI DSS | 9.2.39.2.49.3.1.19.5.1.2 | Physical access to network hardware restricted; Consoles in sensitive areas locked when unattended… | No mapping. Only shares CSF PR.AA-06: related, not a mapping+4 more loosely related (not mappings)9.2.1.1 Access to sensitive areas monitored by camera or access control Only shares CSF PR.AA-06: related, not a mapping 9.3.1 Personnel physical access authorised and managed Only shares CSF PR.AA-06: related, not a mapping 9.3.2 Visitor access authorised, escorted and identifiable Only shares CSF PR.AA-06: related, not a mapping | |
| CMMC | PE.L2-3.10.1PE.L2-3.10.2PE.L2-3.10.3PE.L2-3.10.4 | Limit Physical Access; Monitor Facility… | No mapping. Only shares CSF PR.AA-06: related, not a mapping+2 more loosely related (not mappings) | |
| HIPAA | §164.310(a)§164.310(a)(2)(i)§164.310(a)(2)(iii)§164.310(b) | Facility Access Controls; Contingency Operations… | No mapping. Only shares CSF PR.AA-06: related, not a mapping+4 more loosely related (not mappings) | |
| GDPR | — | No requirement | No mapping in our data | No mapping in our data (only GDPR's security articles are mapped, editorially). |
| NIS2 | 11.513.3 | Identification; Perimeter and physical access control | No mapping. Only shares CSF PR.AA-06: related, not a mapping | |
| Essential Eight | — | No requirement | No mapping in our data | No mapping in our data (Essential Eight links are editorial only). |
| DORA | Art.6(2)Art.9(4)(c) | ICT risk management framework; Protection and prevention | No mapping. Only shares CSF PR.AA-06: related, not a mapping | |
| CPS 234 | — | No requirement | No mapping in our data | No mapping in our data (CPS 234 is principles-based and its links are editorial). |
| Cyber Essentials | — | No requirement | No mapping in our data | No mapping in our data (Cyber Essentials covers five technical controls only). |
Crosswalk a published crosswalk (NIST, ENISA, CIS, PCI SSC) makes the link · Editorial ControlMapping's judgement where no crosswalk exists; the reason is shown · only shares a CSF 2.0 outcome: worth checking, not a mapping · No mapping in our data nothing mapped in our data; often new work, but check the coverage notes. How links are sourced.