Physische Sicherheit
Physischen Zugang zu Gebäuden und Geräten kontrollieren und diese vor Umweltbedrohungen schützen.
Physische Sicherheit wird durch die NIST CSF 2.0 Outcomes PR.AA-06 (Physical access to assets is managed, monitored, and enforced commensurate with risk); DE.CM-02 (The physical environment is monitored to find potentially adverse events); PR.IR-02 (The organization's technology assets are protected from environmental threats) definiert. Crosswalk Über einen veröffentlichten Crosswalk zugeordnet in ISO 27001, PCI DSS, CMMC, 800-53, HIPAA und NIS2. Redaktionell Redaktionell zugeordnet in SOC 2 und DORA. Keine Zuordnung in unseren Daten Keine Zuordnung in unseren Daten für CIS v8.1, GDPR, Essential Eight, CPS 234 und Cyber Essentials.
| Framework | Anforderung | Titel | Verknüpfung | Quelle / Begründung |
|---|---|---|---|---|
| NIST CSF 2.0 | PR.AA-06DE.CM-02PR.IR-02 | Physical access to assets is managed, monitored, and enforced commensurate with risk; The physical environment is monitored to find potentially adverse events; The organization's technology assets are protected from environmental threats | Themendefinition | PR.AA-06 DE.CM-02 PR.IR-02 |
| ISO 27001 | A.7.1A.7.2A.7.3A.7.4A.7.5A.7.8A.7.11A.7.6A.7.12 | Physical security perimeters; Physical entry; Securing offices, rooms and facilities… | Crosswalk | A.7.1: via PR.AA-06; NIST 800-53 map: PE-3 A.7.2: via PR.AA-06; NIST 800-53 map: PE-2, PE-3 A.7.3: via PR.AA-06; NIST 800-53 map: PE-3 A.7.4: via PR.AA-06; DE.CM-02; NIST 800-53 map: PE-3, PE-6 A.7.5: via PR.IR-02; NIST 800-53 map: PE-13, PE-14 A.7.8: via PR.IR-02; NIST 800-53 map: PE-13, PE-14 A.7.11: via PR.IR-02; NIST 800-53 map: PE-14 A.7.6: via PR.IR-02 A.7.12: via PR.AA-06; PR.IR-02 |
| CIS v8.1 | — | Keine Anforderung | Keine Zuordnung in unseren Daten | In unseren Daten ist keine CIS v8.1-Anforderung diesem Thema zugeordnet. |
| SOC 2 | CC6.4 | Physical access restrictions | Redaktionell | CC6.4: AICPA's TSC mappings are not openly licensed; ControlMapping editorial mapping (criterion summaries are ours, not AICPA text). |
| PCI DSS | 9.2.19.2.39.3.19.2.1.19.3.1.19.3.2 | Facility entry controls restrict CDE access; Physical access to network hardware restricted; Personnel physical access authorised and managed… | Crosswalk | 9.2.1: Facility entry controls restrict physical access to the cardholder data environment; NIST's PCI references for these subcategories omit it. 9.2.3: via PR.AA-06 9.3.1: Procedures to authorize and manage physical access of personnel; omitted from NIST's PCI references for these subcategories. 9.2.1.1: Physical access to sensitive areas is monitored with video cameras or access-control mechanisms, and the records kept. 9.3.1.1: via PR.AA-06; DE.CM-02 9.3.2: Procedures to authorise and manage visitor access to the cardholder data environment. |
| CMMC | PE.L2-3.10.1PE.L2-3.10.2PE.L2-3.10.3PE.L2-3.10.4PE.L2-3.10.5PE.L2-3.10.6 | Limit Physical Access; Monitor Facility; Escort Visitors… | Crosswalk | PE.L2-3.10.1: via 800-171r3 03.10.01 ↔ PR.AA-06 → PE-2; 800-171r2 Appendix D → PE-2, PE-6 PE.L2-3.10.2: via 800-171r3 03.10.02 ↔ PR.AA-06, DE.CM-02 → PE-6; 800-171r2 Appendix D → PE-2, PE-6 PE.L2-3.10.3: via 800-171r3 03.10.07 ↔ PR.AA-06, DE.CM-02 → PE-3; 800-171r2 Appendix D → PE-3 PE.L2-3.10.4: via 800-171r3 03.10.07 ↔ PR.AA-06, DE.CM-02 → PE-3; 800-171r2 Appendix D → PE-3 PE.L2-3.10.5: via 800-171r3 03.10.07 ↔ PR.AA-06, DE.CM-02 → PE-3; 800-171r2 Appendix D → PE-3 PE.L2-3.10.6: Enforce safeguarding measures for CUI at alternate work sites. |
| 800-53 | PE-2PE-3PE-6PE-8PE-13PE-14 | Physical Access Authorizations; Physical Access Control; Monitoring Physical Access… | Crosswalk | PE-2: via PR.AA-06 PE-3: via PR.AA-06; DE.CM-02 PE-6: via PR.AA-06; DE.CM-02 PE-8: via PR.AA-06 PE-13: via PR.IR-02 PE-14: via PR.IR-02 |
| HIPAA | §164.310(a)§164.310(a)(2)(ii)§164.310(a)(2)(iii)§164.310(b)§164.310(c) | Facility Access Controls; Facility Security Plan; Access Control and Validation Procedures… | Crosswalk | §164.310(a): via NIST HIPAA map: PE-2, PE-3 §164.310(a)(2)(ii): Facility security plan (safeguard the facility and equipment from unauthorized access, tampering and theft); NIST maps it to PE-1/PL-2-level planning controls rather than this topic's physical access controls. §164.310(a)(2)(iii): via NIST HIPAA map: PE-2, PE-3, PE-6, PE-8 §164.310(b): via NIST HIPAA map: PE-3 §164.310(c): via NIST HIPAA map: PE-2, PE-3 |
| GDPR | — | Keine Anforderung | Keine Zuordnung in unseren Daten | In unseren Daten ist keine GDPR-Anforderung diesem Thema zugeordnet. |
| NIS2 | 13.113.213.3 | Supporting utilities; Protection against physical and environmental threats; Perimeter and physical access control | Crosswalk | 13.1: via DE.CM-02; ENISA ISO map: A.7.11 13.2: via PR.IR-02; ENISA ISO map: A.7.3, A.7.5 13.3: via PR.AA-06; DE.CM-02; ENISA ISO map: A.7.1, A.7.2, A.7.4 |
| Essential Eight | — | Keine Anforderung | Keine Zuordnung in unseren Daten | In unseren Daten ist keine Essential Eight-Anforderung diesem Thema zugeordnet. |
| DORA | Art.6(2)Art.9(4)(c) | ICT risk management framework; Protection and prevention | Redaktionell | Art.6(2): The framework protects physical components and infrastructure, such as premises, data centres and sensitive areas. Art.9(4)(c): Limit physical access to information and ICT assets. |
| CPS 234 | — | Keine Anforderung | Keine Zuordnung in unseren Daten | In unseren Daten ist keine CPS 234-Anforderung diesem Thema zugeordnet. |
| Cyber Essentials | — | Keine Anforderung | Keine Zuordnung in unseren Daten | In unseren Daten ist keine Cyber Essentials-Anforderung diesem Thema zugeordnet. |
Themendefinition CSF-2.0-Ergebnisse, die dieses Thema definieren · Crosswalk mindestens eine Auswahl, gestützt durch einen veröffentlichten Crosswalk · Redaktionell Einschätzung von ControlMapping mit Begründung · nicht zugeordnet, teilt nur die CSF-Ergebnisse dieses Themas · Keine Zuordnung in unseren Daten In unseren Daten nichts zugeordnet; oft neue Arbeit, aber prüfen Sie die Hinweise zur Abdeckung. Methodik.
Anforderungs-IDs und Titel werden so angezeigt, wie jedes Framework sie veröffentlicht, auf Englisch.
Falsche oder fehlende Zuordnung? Melden
Über Physische Sicherheit
Die physische Sicherheit schützt die Gebäude, Räume und Geräte, von denen die Informationssysteme abhängen. Sie umfasst gesicherte Perimeter und Zutrittskontrollen, das Besuchermanagement, die Überwachung des physischen Zugangs, den Schutz vor Brand, Überschwemmung, Stromausfall und anderen Umweltbedrohungen sowie den sicheren Umgang mit Geräten und Datenträgern. Auch cloudorientierte Organisationen haben physische Pflichten für Büros, Endgeräte und jede lokale Infrastruktur, und Auditoren prüfen routinemäßig Badge-Zutritte, Besucherprotokolle und die Entsorgung von Geräten zusammen mit den logischen Kontrollen.