Anomaly Detection
Identify anomalous activity that may indicate a security event.
Anomaly Detection is defined by the NIST CSF 2.0 outcomes DE.AE-02 (Potentially adverse events are analyzed to better understand associated activities); DE.AE-04 (The estimated impact and scope of adverse events are understood); DE.CM-09 (Computing hardware and software, runtime environments, and their data are monitored to find potentially adverse events). Crosswalk Mapped through a published crosswalk in ISO 27001, CIS v8.1, CMMC, 800-53 and NIS2. Editorial Mapped editorially in SOC 2, PCI DSS, Essential Eight and DORA. Only loosely related in HIPAA. No mapping in our data No mapping in our data for GDPR, CPS 234 and Cyber Essentials.
| Framework | Requirement | Title | Link | Source / reason |
|---|---|---|---|---|
| NIST CSF 2.0 | DE.AE-02DE.AE-04DE.CM-09 | Potentially adverse events are analyzed to better understand associated activities; The estimated impact and scope of adverse events are understood; Computing hardware and software, runtime environments, and their data are monitored to find potentially adverse events | Topic definition | DE.AE-02 DE.AE-04 DE.CM-09 |
| ISO 27001 | A.8.16 | Monitoring activities | Crosswalk | A.8.16: via DE.CM-09; NIST 800-53 map: SI-4 |
| CIS v8.1 | CIS 8.11 | Conduct Audit Log Reviews | Crosswalk | CIS 8.11: via DE.AE-02 |
| SOC 2 | CC7.2 | Monitoring system components for anomalies | Editorial | CC7.2: AICPA's TSC mappings are not openly licensed; ControlMapping editorial mapping (criterion summaries are ours, not AICPA text). |
| PCI DSS | 10.4.1.1 | Automated mechanisms for log review | Editorial | 10.4.1.1: Automated mechanisms for audit log review; omitted from NIST's PCI references. |
| CMMC | SI.L2-3.14.7 | Identify Unauthorized Use | Crosswalk | SI.L2-3.14.7: via 800-171r3 03.14.06 ↔ DE.AE-02, DE.CM-09 → SI-4; 800-171r2 Appendix D → SI-4 |
| 800-53 | AU-6SI-4 | Audit Record Review, Analysis, and Reporting; System Monitoring | Crosswalk | AU-6: via DE.AE-02 SI-4: via DE.AE-02; DE.CM-09 |
| HIPAA | §164.308(a)(1)(ii)(D)§164.308(a)(5)(ii)(C)§164.308(a)(6)§164.308(a)(6)(ii)§164.308(a)(8)§164.312(b) | Not mapped to this topic | These requirements only share this topic's CSF outcomes (DE.AE-02, DE.AE-04, DE.CM-09) through published crosswalks: worth checking, not a mapping. | |
| GDPR | — | No requirement | No mapping in our data | No GDPR requirement is mapped to this topic in our data. |
| NIS2 | 3.4 | Event assessment and classification | Crosswalk | 3.4: via DE.AE-04 |
| Essential Eight | ISM-1228 | Cyber security events are analysed in a timely manner to identify cyber security incidents | Editorial | ISM-1228: ASD assigns these ISM controls to the Essential Eight; ASD publishes no crosswalk to NIST or ISO, so linking them to topics is ControlMapping editorial. |
| DORA | Art.10(1) | Detection | Editorial | Art.10(1): Promptly detect anomalous activities, including ICT network performance issues. |
| CPS 234 | — | No requirement | No mapping in our data | No CPS 234 requirement is mapped to this topic in our data. |
| Cyber Essentials | — | No requirement | No mapping in our data | No Cyber Essentials requirement is mapped to this topic in our data. |
Topic definition CSF 2.0 outcomes that define this topic · Crosswalk at least one pick backed by a published crosswalk · Editorial ControlMapping's judgement, with the reason · not mapped, only shares this topic's CSF outcomes · No mapping in our data nothing mapped in our data; often new work, but check the coverage notes. Methodology.
Wrong or missing mapping? Report it
About Anomaly Detection
Anomaly detection uses baseline behavioral profiles and machine learning algorithms to identify deviations from normal patterns in user activity, network traffic, and system operations that may indicate compromise or insider threats. Unlike signature-based detection, anomaly detection can identify novel attacks and zero-day exploits by flagging unusual data transfers, abnormal login times, atypical access patterns, or unexpected process execution. Effective implementation requires establishing accurate baselines, tuning sensitivity thresholds to balance detection rates against false positive volumes, and integrating findings into the incident triage workflow.